IEC 63056 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for secondary lithium cells and batteries for use in electrical energy storage systems

IEC 63056 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for secondary lithium cells and batteries for use in electrical energy storage systems

IEC 63056 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for secondary lithium cells and batteries for use in electrical energy storage systems These tolerances comprise the combined accuracy of the measuring instruments, the measurement techniques used, and all other sources of error in the test procedure. The details of the instrumentation used...

IEC 63057 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for secondary lithium batteries for use in road vehicles not for the propulsion

IEC 63057 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for secondary lithium batteries for use in road vehicles not for the propulsion

IEC 63057 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for secondary lithium batteries for use in road vehicles not for the propulsion The details of the instrumentation used shall be provided in any report of results. 5 General safety considerations 5.1General The safety of lithium secondary batteries requires the consideration of two...

IEC 63060 pdf – Electric energy supply networks – General aspects and methods for the maintenance of installations and equipment

IEC 63060 pdf – Electric energy supply networks – General aspects and methods for the maintenance of installations and equipment

IEC 63060 pdf – Electric energy supply networks – General aspects and methods for the maintenance of installations and equipment This document provides guidance to develop maintenance requirements of installations andequipment in electric power networks. lt is primarily meant for the operators of electric powernetworks, particularly those of public power supplies,including High-Voltage DC transmission(HvDC). This scope does not include: railway...

IEC 63067 pdf – Electrical installations for lighting and beaconing of aerodromes – Connecting devices – General requirements and tests

IEC 63067 pdf – Electrical installations for lighting and beaconing of aerodromes – Connecting devices – General requirements and tests

IEC 63067 pdf – Electrical installations for lighting and beaconing of aerodromes – Connecting devices – General requirements and tests This document applies to plugs and receptacles for single or multiple pole connecting devicesused for aeronautical ground lighting applications. Additional requirements and usage of connecting devices are given in different parts ofIEC 61820 series. Connecting devices complying with this document...

IEC 63077 pdf – Good refurbishment practices for medical imaging equipment

IEC 63077 pdf – Good refurbishment practices for medical imaging equipment

IEC 63077 pdf – Good refurbishment practices for medical imaging equipment scope This document describes and defines the PROCESs of REFURBISHMENT of uSED MEDICALIMAGINGEQUIPMENT and applies to the restoring of uSED MEDICALIMAGING EQUIPMENT to a condition ofsafety and performance comparable to that of new MEDICAL IMAGING EQUIPMENT i.e.MEDICALIMAGING EQUIPMENT that was not in use.This restoration includes actions such as REPAIR,REWORK,software/hardware...

IEC 63078 pdf – Installations for electroheating and electromagnetic processing – Test methods for induction through-heating installations

IEC 63078 pdf – Installations for electroheating and electromagnetic processing – Test methods for induction through-heating installations

IEC 63078 pdf – Installations for electroheating and electromagnetic processing – Test methods for induction through-heating installations 1 Scope This clause of lEC 60398:2015 is replaced by the following. This document specifies the test procedures,conditions and methods for determining themain performance parameters and operational characteristics of induction through-heatinginstallations. Measurements and tests that are solely used for the verification of safety...

IEC 63093-3 pdf – Ferrite cores – Guidelines on dimensions and the limits of surface irregularities – Part 3: Half pot-cores made of ferrite for inductive proximity switches

IEC 63093-3 pdf – Ferrite cores – Guidelines on dimensions and the limits of surface irregularities – Part 3: Half pot-cores made of ferrite for inductive proximity switches

IEC 63093-3 pdf – Ferrite cores – Guidelines on dimensions and the limits of surface irregularities – Part 3: Half pot-cores made of ferrite for inductive proximity switches 1 Scope This part of lEC 63093-3 specifies the dimensions that are of importance for mechanicalinterchangeability for a preferred range of half pot-cores made of ferrite,intended to be usedin inductive proximity switches.Half...

IEC 63093-9 pdf – Ferrite cores – Guidelines on dimensions and the limits of surface irregularities – Part 9: Planar-cores

IEC 63093-9 pdf – Ferrite cores – Guidelines on dimensions and the limits of surface irregularities – Part 9: Planar-cores

IEC 63093-9 pdf – Ferrite cores – Guidelines on dimensions and the limits of surface irregularities – Part 9: Planar-cores 1 Scope This part of lEC 63093 specifies the shapes and dimensions of ferrite cores for inductivecomponents (transformers and chokes), whose the coil is typically made of multi-layer boards (or the coilis part of the motherboard), and theeffective parameter’values used...

IEC 63115-2 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Sealed nickel-metal hydride cells and batteries for use in industrial applications – Part 2: Safety

IEC 63115-2 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Sealed nickel-metal hydride cells and batteries for use in industrial applications – Part 2: Safety

IEC 63115-2 pdf – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Sealed nickel-metal hydride cells and batteries for use in industrial applications – Part 2: Safety 5 General safety considerations5.1General The safety of sealed nickel-metal hydride cells or batteries requires the consideration of twosets of applied conditions: a) intended use; b) reasonably foreseeable misuse. The manufacturer...

IEC 63129 pdf – Determination of inrush current characteristics of lighting products

IEC 63129 pdf – Determination of inrush current characteristics of lighting products

IEC 63129 pdf – Determination of inrush current characteristics of lighting products This document describes a method, based on measurements combined with calculations,todetermine specific characteristics of the inrush current of single and/or multiple lighting products of the same type. Lighting products include the following: – light sources with integrated controlgear, -controlgear, -luminaires. The inrush current characteristics that are determined are....