1 Scope
This part of lEC 60317 specifies the requirements of polyester glass-fibre wound resin/varnish
impregnated,bare,grade 1 or grade 2 enamelled round copper winding wire,temperatureindex 180.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot beestablished. Consequently,a class based on the requirements for temperature index and heat shock temperaturecannot be specified.
The nominal conductor diameters are specified in IEC 60317-O-10:2017,Clause 4.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60317-0-10:2017,Specifications for particular types of winding wires – Part 0-10: General
requirements – Polyester glass-fibre wound fused, unvarnished, or resin or vamishimpregnated, bare or enamelled round copper wire
3Terms,definitions,general notes and appearance
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in lEC 60317-0-10 apply.
ISO and IEC maintain terminological databases for use in standardization at the followingaddresses:
. IEC Electropedia: available at http://www.electropedia.orgl
. Iso Online browsing platform: available at http://www.iso.org/obp3.2General notes
3.2.1Methods of test
Subclause 3.2.1 of IEC 60317-0-10:2017applies. In case of inconsistencies betweenIEC 60317-0-10 and this document, the latter shall prevail.
3.2.2Winding wire
The fibre covering shall consist of a combination of polyester and glass fibres. The glassfibres shall be electrical-grade continuous-filament glass yarn. The polyester fibre shall be ahigh-grade yarn resulting from the linear polymerization of ethylene glycol and terephthalicacid.The maximum content by weight of polyester fibre in the yarn shall not exceed 50 %.
The enamelled wire shall have a temperature index of at least 180 and shall be agreed between purchaser and supplier.
The temperature index of the wire is dependent upon the type of impregnating agent used.
The impregnating agent applied to the polyester glass fibre shall have a minimum temperature index of 180.
The covering shall have one of the following grades of thickness:
– PG1: bare conductor with 1 layer of polyester glass fibre or 2 layers of finer polyester glass fibres that together, comply with the dimensional requirements in IEC 60317-0-10;
– PG2: bare conductor with 2 layers of polyester glass fibre;
– grade 1 PG1: enamelled grade 1 (grade 1) with 1 layer of polyester glass fibre (PG1);
– grade 1 PG2: enamelled grade 1 (grade 1) with 2 layers of polyester glass fibre (PG2);
– grade 2 PG1: enamelled grade 2 (grade 2) with 1 layer of polyester glass fibre (PG1);
– grade 2 PG2: enamelled grade 2 (grade 2) with 2 layers of polyester glass fibre (PG2).
3.3 Appearance
Subclause 3.3 of IEC 60317-0-10:2017 applies.
4 Dimensions
Clause 4 of IEC 60317-0-10:2017 applies.
5 Electrical resistance
Clause 5 of IEC 60317-0-10:2017 applies.
6 Elongation
Clause 6 of IEC 60317-0-10:2017 applies.
7 Springiness
Clause 7 of IEC 60317-0-10:2017 applies.
8 Flexibility and adherence
Clause 8 of IEC 60317-0-10:2017 applies.
9 Heat shock
Test inappropriate.
10 Cut-through
Test inappropriate.
11 Resistance to abrasion
Test inappropriate.
12 Resistance to solvents
Test inappropriate.
13 Breakdown voltage
Clause 13 of IEC 60317-0-10:2017 applies.
14 Continuity of insulation
Test inappropriate.
15 Temperature index
Clause 15 of IEC 60317-0-10:2017 applies.
16 Resistance to refrigerants
Test inappropriate.
17 Solderability
Test inappropriate.
18 Heat or solvent bonding
Test inappropriate.
19 Dielectric dissipation factor
Test inappropriate.
20 Resistance to transformer oil
Test inappropriate.
21 Loss of mass
Test inappropriate.
23 Pin hole test
Test inappropriate.