IEC 60286-1 pdf – Packaging of components for automatic handling – Part 1: Tape packaging of components with axial leads on continuous tapes

IEC 60286-1 pdf – Packaging of components for automatic handling – Part 1: Tape packaging of components with axial leads on continuous tapes

IEC 60286-1 pdf – Packaging of components for automatic handling – Part 1: Tape packaging of components with axial leads on continuous tapes
1Scope
This part of lEC 60286 applies to the tape packaging of components with axial leads for use inelectronic equipment. In general, the tape is applied to the component leads.
lt covers requirements for taping techniques used with equipment for the preforming of leads,automatic handling, insertion and other operations, and includes only those dimensions whichare essential to the taping of components intended for the above-mentioned purposes.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies.For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60294,Measurement of the dimensions of a cylindrical component with axial terminationsISO 11469,Plastics – Generic identification and marking of plastic products
3Terms and definitions
No terms and definitions are listed in this document.
lsO and lEC maintain terminological databases for use in standardization at the followingaddresses:
IEC Electropedia: available at http://www.electropedia.orgl
Iso Online browsing platform: available at http://www.iso.orgl/obp
4Dimensions
4.1 Dimensions common to tapes and taped components with axial leads4.1.1General
The general configuration is shown in Figure 1, Table 1 and Table 2.
4.1.2 Body location (permissible lateral deviation) Dimension K, being the width of the window in which the component body shall be located, shall be 1,0 mm (for B = 26 mm) or 1,4 mm (for B > 26 mm) wider than the maximum length L IEC 60294. of the component body. The latter is the body length measured in accordance with max Unless otherwise specified, the window shall be centrally located between the tapes. When a gauge measurement to determine dimension K is impractical, it is possible to measure the distances L and L 2 of the leads. The difference between L 1 and L 2 shall not 1 exceed 1,0 mm (for B = 26 mm) or 1,4 mm (for B > 26 mm).