1 Scope
This part of lEC 63138, which is a sectional specification(SS), provides information and rules
for the preparation of detail specifications (DS) for MQ4 series circular connectors with fourRF channels, as well as a detailed specification of the blank format.
An MQ4 series circular connector with 50 Q nominal impedance has four RF channels whichcan be engaged and disengaged at the same time.There are two versions of plug connectors,
one is a quick-lock version,and the other is a threaded version. The socket connectorprovides two coupling mechanisms, a quick-lock and a threaded coupling.
MQ4 series circular connectors can be used in mobile communication systems and in othercommunication equipment.
This document also specifies the mating face dimensions and gauging information of MQ4series circular connectors,and tests selected from IEC 63138-1,applicable to all detailspecifications relating to MQ4 series circular connectors.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies.For undated references, the latest edition of the referenced document(including
any amendments) applies.
IEC 63138-1:2019, Multi-channel radio frequency connectors – Part 1: Generic specification-General requirements and test methods
3 Terms and definitions
For the purposes of this document, the terms and definitions given in lEC 63138-1 apply.
ISo and IEC maintain terminological databases for use in standardization at the followingaddresses:
.IEC Electropedia: available at http://www.electropedia.orgl
.IsO Online browsing platform: available at http://www.iso.org/obp
4Mating face and gauge information
4.1 Mating face dimensions
4.1.1 MQ4 socket connector
The mating face of MQ4 socket connectors is shown in Figure 1 and its dimensions are shownin Table 1.