IEC 60317-25 pdf – Specifications for particular types of winding wires – Part 25: Polyester or polyesterimide overcoated with polyamide-imide enamelled round aluminium wire, class 200
1 Scope
This part of IEC 60317 specifies the requirements of enamelled round aluminium windingwires’ of class 200 with a dual coating. The underlying coating is based on polyester orpolyesterimide resin,which can be modified provided it retains the chemical identity of theoriginal resin and meets all specified wire requirements. The superimposed coating is basedon polyamide-imide resin.
NOTE A modfied resin is a resin that has undergone a chemical change,or contains one or more addtives toenhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this document is:- Grade 1: 0,250 mm up to and including 3,150 mm;
– Grade 2: 0,250 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 andIEC60317-0-3:2008/AMD1:2013.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies. For undated references, the latest edition of the referenced document (inciuding
any amendments) applies.
IEC 60317-0-3: 2008,Specifications for particular types of winding wires – Part 0-3: Generalrequirements – Enamelled round aluminium wire
IEC 60317-0-3: 2008/AMD1:2013
IEC 60317-0-3:2008/AMD2:2019
3 Terms,definitions,general notes and appearance3.1Terms and definitions
For the purposes of this document, the terms and definitions given in lEC 60317-0-3 apply.
IsO and lEC maintain terminological databases for use in standardization at the followingaddresses:
IEC Electropedia: available at http://www.electropedia.orgl
. Iso Online browsing platform: available at http:.l/www.iso.orglobp
3.2General notes3.2.1Methods of test
Subclause 3.2.1 of lEC 60317-0-3:2008,IEC 60317-0-3:2008/AMD1:2013 and lEC 60317-0-3:2008/AMD2:2019applies. In case of inconsistencies between IEC 60317-0-3and thisdocument,IEC 60317-25 shall prevail.
3.2.2Winding wire
Class 200 is a thermal class that requires a minimum temperature index of 200 and a heatshock temperature of at least 220°c.
The temperature in degrees Celsius corresponding to the temperature index is not necessarily
that at which it is recommended that the wire be operated and this will depend on manyfactors, including the type of equipment involved.
3.3Appearance
Subclause 3.3 of lEC 60317-0-3:2008 applies.
4Dimensions
Clause 4 of lEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013 applies.
5 Electrical resistance
Clause 5 of lEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD2:2019 applies.
6Elongation
Clause 6 of lEC 60317-0-3:2008 applies.
7 Springiness
Test inappropriate.
8Flexibility and adherenceClause 8 of lEC 60317-0-3:2008 applies.
9Heat shock
Clause 9 of IEC 60317-0-3:2008 applies. The minimum heat shock temperature shall be220 °c.
10 Cut-through
No failure shall occur within 2 min at 320°C.